# Figures of journal note 26 (protocol 022's conductance follow-up)

Both figures are drawn by `draw_conductance.py` from the CSVs that `make_conductance_csv.py` wrote from this package's
`results/readings-a.json`. No other input, no image generator. The CSVs carry every plotted number, and the CSV maker
recomputes each combination's value from the condition means and refuses to write on a mismatch.

## Figure 1: `conductance-readings` (`.png`, `.svg`; data `conductance-readings.csv`)

**Caption.** The three declared readings for layer 4 excitatory cells tuned to one grating of an orthogonal plaid,
instance A. Dots: the eight combinations of a cell group (45° or 135°) and a block A plaid, each with its 95 %
interval; diamond: the pooled reading with its 95 % interval (10,000 resamplings of whole steps). Left: the mean
afferent conductance a plaid evokes over the sum of what its two gratings evoke alone (A_aff; 1 would be additive).
Middle and right: the change of the inhibitory (m_I) and of the intracortical excitatory (m_E) conductance when the
second grating is added, as a share of what the first grating evoked; dashed lines mark the declared margin of 0.10.
Exploratory, one instance, conductances rebuilt from recorded spikes. Simulation only.

**Alt text.** Three dot panels titled "The second grating lowered inhibition, and cortical excitation more". Panel 1,
afferent additivity, on a scale from 0 to 1.1 with a line at 1 labelled sum of the two singles: eight dots between
0.51 and 0.68 and a pooled diamond at 0.622. Panel 2, inhibition, on a scale from −0.8 to 0.3 with a line at 0
labelled no change and dashed margin lines at ±0.10: eight dots between −0.25 and +0.01 and a pooled diamond at
−0.145. Panel 3, cortical excitation, same scale: eight dots between −0.64 and −0.04 and a pooled diamond at −0.389.

## Figure 2: `conductance-conditions` (`.png`, `.svg`; data `conductance-conditions.csv`)

**Caption.** Mean conductance onto the layer 4 excitatory cells preferring 45° (915 cells), by source, and the cells'
own firing, for the blank, their own grating, the orthogonal grating and the plaid of the two, all at 30 % contrast,
in the window 20 to 230 ms after onset. Means without intervals; the CSV also holds the 135° group (1,071 cells),
which the figure does not draw. The mean afferent conductance is nearly the same for the cells' own grating and the
orthogonal one, so it does not carry orientation; the cortical conductances and the firing do.

**Alt text.** Four bar panels titled "The mean input from the LGN does not tell the two gratings apart", each with
bars for blank, own grating, orthogonal grating and plaid. Afferent conductance in nanosiemens: 1.05, 1.24, 1.26,
1.27. Cortical excitation: 0.28, 0.97, 0.39, 0.63. Inhibition: 3.28, 5.73, 4.41, 5.13. The cells' own firing in
spikes per cell per step: 0.45, 3.30, 0.50, 1.49.

Model: 2 mm reduction of LSV1M (Antolík et al. 2024, CC BY 4.0), simulated with Mozaik and NEST 3.4.